Construction and Function
34
56217Construction
Function
1Housing•The measuring gears are driven by the liquid flow 2Coveron the principle of a gear motor.3Gear
•The gears run without contact in the measuring 4Preamplifierchamber. The bearing elements are low-friction ball 5Connectoror plain bearings.6Sensor
•The movement of the gears is sampled without contact7
Bearing assembly
by means of two sensors located in the cover.
Between sensor compartment and measuring chamberis located a pressure-resistant, non-magnetic separatorplate.•When the measuring mechanism rotates by one
tooth pitch, the sensor emits a signal which correspondsto the geometrical tooth volume Vgz.•The signal is converted into a square-wave signal by the preamplifier.•The two-channel sampling permits better resolution as well as recognition of the flow direction.
KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.eu3
GearType Flow Meter VC
Product Characteristics
•Optimized for individual applications because the series have been rendered media-specific by means of differing clearances, bearing variantsand materials.•Wide measuring ranges with sizes graduated tomeet specific requirements.•Measurement independent of viscosity within the specified ranges.•Low pressure drop
•High-response measurement •High operating pressure•Low noise emission
•High-precision measurement with outstanding reproducibility•Temperature-independent output signals over a widetemperature range•High degree of accuracy, even with low flow rates at the bottom end of the measuring range•High operating reliability of the electronics•Easy to use terminal of the preamplifier•Operating indication of the electronic
•Sensor system and preamplifier in EMC-compatible design•Explosion-proof version available for all volume counters
Typical Applications
Application
Flow rate measurement(hydraulic test stand)
Medium
oil, brake fluid, skydrol, diesellubricatinglow viscositygear oillubricating
medium viscosityoffset inklubricatinghigh viscosity
polyol+isocyanate, adhesives, resin, siliconlow lubricity
medium viscosity
clear lacquer, cavity waxeslow lubricity
medium viscositysolventlubricatinglow viscosity
Version
cast iron
ball bearings
minimal clearancescast iron
ball bearings
increased clearancescast iron
bronze plain bearingslarge clearancescast iron
carbide plain bearingsincreased clearancesstainless steel
carbide plain bearingsincreased clearancesstainless steelball bearings
minimal clearances
Series
123456
Oil metering(metering plant)
Consumption measurement(Printing press)
Ratio control
(2 component plant)
Batching control(lacquering plant)
Flow rate measurement(lacquering plant)
For fluids with a low viscosity and poor lubricity a hybrid ball bearing (with ceramic balls)is a available for sizes VC 0.025, VC 0.04, VC 0.2 and VC1.
Flow meters with hydrid ball bearing are available in cast iron (series7) and stainless steel (series 8).
4KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.euGearType Flow Meter VC
Accuracy Characteristics
•The accuracy figures quoted by KRACHT refer
•Accuracy checking forms part of quality inspection to the geometric tooth volume Vgz, that is to say the in every case.percentage deviation applies to the current value in each case.•On request the result of the test will be documentedin the form of an accuracy characteristic curve;
•The linearity error over the entire measuring range an example relating to a series 1 VC1 is given below.is<±0.1%•The accuracy values quoted by Kracht are confirmed•Reproducibility of a measured value is <0.1%
by the DKD (German Calibration Service).
Accuracy
1.05
cm3
1.045esl1.04u+ 0.3%p rVgz= 1.036ep-- 0.3%
1.035emulVo1.031.0251.02
0 10 20 30 40 50 60 70 80
l/min
Flow rate Q
Linearity
1.05
cm3
1.045esl1.04up + 0.1%repVgz= 1.036 1.035e-- 0.1%
mulVo1.031.0251.02
0 10 20 30 40 50 60 70 80
l/min
Flow rate Q
KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.eu5
GearType Flow Meter VC
General Characteristics
DesignConnection typeMounting positionSealing materialsAmbient temperatureMedium temperaturefor standard versionMedium temperaturefor high temperature versionfor high temp. PLUS versionMedium temperaturefor-versiongear motorplate mounting/pipe connectionoptionalFlow directionViscosityMax. pressure dropoptional1...1000000 mm2/s, according to seriesΔpmax= 16 barFEP
--30°C– +80°C--30°C– +120°C--30°C– +80°C--30°C– +150°Con request--30°C– +220°C--30°C– +80°C--30°C– +80°CFFKM
--15°C– +80°C--15°C– +120°C--15°C– +80°C--15°C– +150°Con request--15°C– +220°C--15°C– +80°C--15°C– +80°CSeries 1,2,6,7,8Series 3,4,5Series 1,2,6,7,8Series 3,4,5Series 1,2,6,7,8Series 1,2,6,7,8Series 3,4,5FKM
--15°C– +80°C--15°C– +120°C--15°C– +80°C--15°C– +150°Con request--15°C– +150°C--15°C– +80°C--15°C– +80°CEPDM
--30°C– +80°C--30°C– +120°C--30°C– +80°C--30°C– +130°Con request–--30°C– +80°C--30°C– +80°CSeries Selection/Summary of Variants
SeriesMaterial housingMaterial gearsBearing1cast ironGGG40(/79 GGG 60)steel1.7139ball bearings2cast ironGGG 40steel1.7139ball bearingsP303cast ironGGG 404cast ironGGG 4056stainless steelstainless steel1.44041.44047cast ironGGG 408stainless steel1.4404ConnectionPMax. perm. foreign particle20size in the medium (μm)Accuracy±0.3 %(from measuring value)at ≥20 mm2/sstainless steelstainless steelsteelstainless steelsteelsteel1.71391.71391.44621.44621.71391.4462stainless steelhybridhybridbronzecarbidecarbideplain bearingsplain bearingsplain bearingsball bearingsplain bearingsball bearingsPPP/RP/RPP/R503030202020±0.5 %±1 %±0.5 %±0.5 %±0.3 %±1 %±1 %222222at ≥50 mm/sat ≥100 mm/sat ≥100 mm/sat ≥100 mm/sat ≥20 mm/sat ≥20 mm/sat≥20mm2/sNominalsize0.0250.040.10.20.41351216Startingpoint at[l/min]0.0010.0040.0080.0100.0100.0200.0300.0400.1000.200Measuring range [l/min]0.008–20.02–40.04–80.16–160.2–400.4–800.6–1601–2502–6003–700–––0.16 – 16–0.4 – 800.6 – 1601– 250–––––––0.6 – 40–1.2 – 80–––––0.16 – 160.2 – 300.3 – 600.6 – 1001 – 160––0.02 – 2*––0.16 – 160.2 – 300.3 – 600.6 – 1001 – 160––0.008 –20.02 – 40.04 – 80.16 – 160–0.4 – 800.6 – 1601 – 250––0.008 –20.02 – 40.04 – 80.16 – 16–0.4 – 80––––0.008 –20.02 – 40.04 – 80.16 – 16–0.4 – 80––––*Measuring accuracy ±3%;Linearity ±1.5%
Operating Characteristics
Nominalsizegeom.toothvolumeVgZcm30.0250.040.100.2450.401.0363.0005.22212.00016.000max. operating pressureStandard-High pressureversionversion (/79)pmaxpmaxbarbar400–400–400–400–400–400–315400315400400–400–Peak pressureSound pressurelevelStandard-High pressureversionversion (/79)^^ppLAbarbardB (A)480–< 60480–< 60480–< 60480–< 60480–< 70480–< 70350480< 70350480< 72480–< 80480–< 80ResolutionImp/l 40000.0025000.0010000.004081.632500.00965.25333.33191.5083.3362.500.0250.040.10.20.413512166
KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.euGearType Flow Meter VC
Type Key
Ordering example
means:
VC0.2F1PS/..Nominal size 0.2 / Seal FKM /Series 1 / Plate mounting / Electronic standard
Special IDNo.ElectronicsSstandard (--30°C … +120°C)Connection typeHhigh temperature (--30°C … +150°C)PPlate mountingKhigh temperaturePLUS(--30°C … +220°C)RPipe connectionVwithout preamplifier (for plug-in display SD1)Xintrinsically safe (ATEX)Series(switching amplifier has to be ordered separately)1· 2· 3· 4· 5 · 6 · 7· 8see series selectionSealFFKMEEPDMPFEPKFFKMNominal size0.025 · 0.04 · 0.1 · 0.2 · 0.4 ·1 · 3 · 5 · 12 · 16Product codeSpecial Versions
Special ID
SeriesDescription
55
1–8
version with aluminium connection box and preamplifier VV12with Cannon plug
711–8version with Hirschmann connector and round connector M12x174
1–8
version with Hirschmann connector and preamplifier VV12for 12 Volt power supply(10.5 –16 Volt)
791VC3andVC5 in high pressure version (400 bar)
155
1
VC3andVC5 in high pressure version (400 bar)
Skydrol resistant, with aluminium connection box and Cannon plug.1561
Skydrol resistant, with aluminium connection box and Cannon plug.
KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.eu7
GearType Flow Meter VC
Electrical Connection
Standard version/High temperature version24 Volt (brown)Signal output channel 2High temperature PLUS version
Electrical connection(Round connector M12x1/4-pin)(4)Channel1 (black)
(1)24 V (brown)
Channel 1 (green)Signal outputchannel 2Channel2 (yellow)0 Volt (white)(3)0 V(blue)(2)Channel2(white)Electrical Characteristics
Number ofmeasuring channelsOperating voltagePulse amplitudePulse shape withsymm. output signal
2
Uop= 12...30 VDCpolarizedUA≥0.8 UB
square wave
pulse duty factor/channel1:1 ±15%
PNP(NPN on request)
Degree of protectionPulse offset betweentwo channelsPower requirementOutput power/channel
90°±30°Pbmax= 0.9 WPamax= 0.3 Wshort-circuit-proofIP 65 DIN 40050
Signal output
Signal Characteristics
Channel IBCDA
131Arising edge
Bone pulse
(corr. to flow rate of geom. tooth volume Vgz)Cfalling edgeDON phaseEOFF phase
Fpulse duty factor 1:1 ±15%Channel
I24FE±15°II
IIGchannel offsetHflow direction 1
Kreversal of flow directionJflow direction 2
G
±30°90°KHJ8KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.euUAUAGearType Flow Meter VC
Explosion-Proof Design (ATEX)Function
•All volume counters are available in explosion-proof•Volume counter and switching amplifier are design according to ATEX.electrically connected to each other. The switching•The explosion-proof design consists of the volume counteramplifier evaluates the sensor signals and converts(intrinsically safe electrical apparatus) and the switchingthem to square-wave signals.amplifier K130 (associated electrical apparatus). •Without switching amplifier, the volume counter must notThe type of protection „intrinsic safety“ applies to thisbe operated in the potentially explosive atmosphere.construction.•Cable lengths of up to 400m are possible between•The volume counter is installed in the potentially volume counter and switching amplifier.explosive atmosphere.•LED’s for monitoring line breaks / short circuits, •The mounting of the amplifier K130 is carried out channel switching state and power supply are locatedin the safe area.on the switching amplifier.Safe areaPotentially explosive atmospherebrownwhitebrownChannel 1Channel 2K130shieldwhiteVC2219631185201741130 Volt24 Voltgreenyellow7, 8 and 9 jumperedPAgreenyellowII(2)G [EExia]IICPTB 03 ATEX 2094 XII2GD EExiaIICT4PTB 03 ATEX 2249Note:This graph is an example only. National laws for potentially explosive areas must be considered. Technical Data of Switching Amplifier K-130/3-E-10Power supplySupply voltage cl.7 (L+), cl.10 (L--)DC 24 Volt ±20 % Ripple content white Wss< 10 %Outputs (non-intrinsically safe)Characteristics cl. 9, 12, 8, 11Electronics outputselectrically isolated via optoelectronic couplerShort-circuit currentapprox. 25 mA
Signal level 1-signal0.8 x supply voltage with RL > 2k ohmSignal level 0-signal
inhibited output, residual current <10 uAAmbience conditions
Minimum limiting temperature248 K (--25°C)
Maximum limiting temperature333 K (+60°C)
MechanicsDimensions
107.5 x 92 x 22 mm
Connection possibilitycan be snapped on a 35 mm mounting channel DIN 46277Weight
approx. 150 g
KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.eu9
GearType Flow Meter VC
Pressure Drop
Series 1, 2, 6, 7 and 8 Parameter: Viscosity (mm2/s)
20001000
600
300
160005000300020001000bar
16141210864200
bar
1614121086420
Pressure dropΔp100Pressure dropΔp6003003420
0.5
1
1.5
2.0
l/min
100340.0
0.1
0.2
0.3
0.4
0.5
l/min
VC 0.025
20001000600
300
Flow rate Q
VC 0.025 (extract)
16000500040003000Flow rate Q
bar
16141210864200
bar
1614121086420
20001000600Pressure dropΔp100
Pressure dropΔp3410
0.5
1
1.5
2
2.5
3
3.5
4
l/min
3001000.0
0.1
0.2
0.3
0.4
0.5
l/min
VC 0.04
6000200030001000Flow rate Q
VC 0.04 (extract)
30002000
1000
Flow rate Q
bar
1614121086420
600300bar
16141210864200
600
Pressure dropΔpPressure dropΔp100
300
3420105
10034
0246810
l/min
246810121416
l/min
VC 0.1
10
Flow rate Q
VC 0.2
Flow rate Q
KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.euGearType Flow Meter VC
Pressure Drop
Series 1, 2, 6, 7 and 8 Parameter: Viscosity (mm2/s)
1614
100345
Pressure dropΔp1210864200
5
10
15
20
25
30
35
40
l/min
300020001000600300
barbar
1614121086420030001000600300Pressure dropΔp10034101020304050607080l/min
VC 0.4
Flow rate Q
VC 1
161412108642005010015030002000Flow rateQ1000600300100341014121086420020406080100120140160l/min
Pressure dropΔp100345Pressure drop Δpbar
16300020001000600300bar
200250l/min
VC 5
15000800010000600030002000Flow rateQ
VC 3
1614121086420010020030040014000800093006000300020001000600Flow rateQ
3001003410006003001003410barbar
1614121086420Pressure drop ΔpPressure drop Δp300300100345100345500600l/min
0100200300400500600700l/min
VC 12
Flow rateQ
VC 16
Flow rateQ
11
KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.euGearType Flow Meter VC
Pressure Drop
Serie 3 Parameter:Viscosity (mm2/s)
1614121086420010203040l/min
300020001000600300100barbar161412108642001020304050607080l/min30002000Pressure dropΔpPressure dropΔp1000600300100VC1
Flow rateQ
VC 5
Flow rateQ
12KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.euGearType Flow Meter VC
Pressure Drop
Series 4/5 Parameter: Viscosity (mm2/s)
16141210864200
2
4
6
8
10
l/min
90003000600020001000600300barbar
161412108642002300020001000600Pressure dropΔp ΔpPressure dropΔp300100
3420105
1003446810121416l/min
VC 0.1
30002000
1000
Flow rate Q
VC 0.2
30001000Flow rate Q
bar
16141210864200
600
bar
1614121086420
600Pressure dropΔpPressure dropΔp3003001003451003451015202530
l/min
0102030405060
l/min
VC 0.4
30002000Flow rate Q
1000VC1
3000Flow rate Q2000100060030010034bar
1614121086420020bar
16141210864200
40
Pressure dropΔp30010034Pressure dropΔp600406080100l/min
80120160
l/min
VC 3
Flow rate Q
VC 5
Flow rate Q
KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.eu13
GearType Flow Meter VC
Dimensions
Series 1, 2, 3, 4, 7–Connection type P
NominalsizeAvailableseriesWeightTighteningtorquekgNmm
VC 0.025VC 0.04VC 0.1VC 0.2VC 0.4VC 1VC 3VC 5
1, 71, 711, 2, 4, 71, 41, 2, 3, 4, 71, 2, 41, 2, 3, 4
1.822.323.75.29130MA14014014014035035012001200A85858585100120170170
C109101317131822
D606060609095120120
F50566557637289
GS101107116108114123140
DimensionsmmGH114120129121127
J–––––
K7070707080844646
L4040404038729595
M2020202034355050
N6.56.56.790160160250250PM 6M 6M 6M 6M 8M 8M12M12
13615.5153169
46.546.5
1050156
7217J34FGSO-RingCPNMVersion Sand Version XVersion HPTightening torque MAConnection dimensionsMKADLNK14KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.euLGHGearType Flow Meter VC
Dimensions
Series 1– High pressure version (/79)
NominalWeightTighteningDimensionssizetorquekgNmmmm
MACDFGSGHJKLMNPVC 316.314524.51809915016346.546955025M12VC 5
18.9
145
22.0180
115
166
179
46.5
46
95
50
25
M12
Series 1– Standard version
NominalWeightTighteningDimensionssizetorquekgNmmmm
MACDFGSGHJKLMNPVC 1253.540044249168219232771201407038M20VC 16
57.4
400
44
249
184
235
248
77
120
140
70
38
M20
7217J34SH GG FPCNMPLLMNKKø DKRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.eu15
GearType Flow Meter VC
Dimensions
Connection plate(cast iron) for VC3/79 and VC5/79(high pressure) with side SAE flange connectionOrderingcodeMVC5 V1E09*Weightkgm14.2DimensionsmmABC90EFGM8/15tK46L95M50N25PM12/24tR50a57.2b27.8ef18015011011025M12/24t* fits for VC3 and VC5
Connection plate for VC12 and VC16 with side SAE flange connectionOrderingcodeWeightkgmMVC12 V1G09**41.2DimensionsmmABCEFGKLMN38PM20/45tR70a79.4b36.5e38fM16/25t249200140120140M10/20t12014070** fits for VC12 and VC16
ø AEfGCRBeaø AbFXXPLMNK16KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.euGearType Flow Meter VC
Dimensions
Series 5, 6 and 8 (stainless steel) – Connection type P
NominalAvailableWeightTighteningDimensionssizeseriestorquekgNmmmmMACDFGSGHJKLMNPVC 0.0255, 6, 83.0140159455106119–7040206.5M6VC 0.046, 83.014099456107120–7040206.7M6VC 0.16, 83.0140109465116129–7040206.7M6VC 0.25, 6, 83.1140139457108121–7040209.0M6VC 0.454.83501711863114127–80383416,0M8VC 15, 6, 87.0350131247212313615.584723516.0M8VC 35, 615.91200211708914015346.546955025.0M12VC 55, 618.7120025170105015616946.546955025.0M12721734JHSGGFO-RingØ DØ NCVersion SMVersion Hand Version XTightening torque MAPConnection dimensionsLMLKØ NKKRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.eu17
GearType Flow Meter VC
Dimensions
Series 5, 6 and 8 (stainless steel) – Connection type R
NominalsizeAvailableseriesWeightkgmVC 0.025VC 0.04VC 0.1VC 0.2VC 0.4VC 1VC 3VC 55, 6, 86, 86, 85, 6, 855, 6, 85, 65, 63.03.03.03.14.87015.918.7AG 1⁄8G 1⁄4G 3⁄8G 3⁄8G 1⁄2G 1⁄2G 1G 17217JDimensionsmmB913131315151919C1721252529294242D94949494118124170170E90909090112120162162F55566557637289105GS106107116108114123140156GH119120129121127136153169H1515201617.5223030J–––––15.546.546.5K7070707080844646L4040404038729595P6.76.76.76.7M89.13.13.ØP Ø DVersion S
and Version XHFGSØ CAVersion H
BLK18KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.euEGHGearType Flow Meter VC
DimensionsVC High Temperature PLUS
NominalWeightTighteningDimensionssizetorquekgNmmmm
MAACDFGPJKLMNPVC 0.0251.8148510605087–7040206.5M 6VC 0.04214859605693–7040206.5M 6VC 0.12.31485106065102–7040206.7M 6VC 0.22148513605794–70402090M 6VC 0.43.735100179063100–803834160M 8VC 15.23512013957210918.5847235160M 8VC 39120170181208912611469550250M12VC 5
130120
170
22
120
105
142
11
46
95
50
250M12
High temperature PLUS areaNormal areaD58Lengths ordering designations64J5812,4Tightenningtorque6341PGF63O-Ring
MCØ 4,3LP46KAView XPConnection dimensionsMLNKKRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.eu19
GearType Flow Meter VC
Dimensions VC High Temperature PLUS
Nominalsize
Weightkgm
TighteningtorqueNm
MA120120400400
C24.522.044.044.0D180180249249
F99115168184
GP136152205235
Dimensions
mmJ–111111
K464612001200L959514001400M50507070
N25253838
PM12M12M20M20
VC 3/79VC 5/79VC 12VC 16
16.318.953.557.4
High temperature PLUS area586414JNormal area5812,4Lengths ordering designationsGPFCNMP46View XConnection dimensionsPLMLNKø DK20KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.eu3614Tightenningtorque36Ø 4,3GearType Flow Meter VC
Connection plates (cast iron) with side threaded connection
OrderingWeightDimensionscodekgmmmABCEFGHJKLMNPRcdefMVC 0.2 R 3 B 05*1.8859035657671177040206.5M6/14t170.725G3⁄813MVC 0.2 R 3 C 05*1.7859035657671177040206.5M6/14t17.50.729G1⁄215MVC 0.4 R 1 C 092.7100110378696711780383416.0M8/18t18.50.729G1⁄215MVC 0.4 R 1 D 092.9100110428696711780383416.0M8/18t21136G3⁄417MVC 1 R 2 C 052.91001203780106711784723512.0M8/18t17.50.729G1⁄215MVC 1 R 3 D 054.91201204280106711784723513.0M8/18t21136G3⁄417MVC 1 R 2 E 054.91001206580106711884723513.0M8/18t32.5142G119MVC 5 R 2 E 05**14.016016580140145915946955025.0M12/24t28142G119MVC 5 R 2 G 09**17.8170165100140145915946955025.0M12/24t42158G11⁄223* fits for VC 0.025,VC 0.04,
VC 0.1 and VC 0.2
AøH** fits for VC 3 and VC 5
EKJCRøGPBFLMView XNCfDRecøGdAnsicht XXConnection plates (cast iron) with side SAE flange connection
Ordering WeightDimensionscodekgmmm
A
B
C
E
F
GHJKLMNP
R
a
b
e
f
MVC 5V2E 05**1416016580140145915946955025M12/24t4057.227.825M12/24tMVC 5V1F0915.116016590140145915946955025M12/24t5066.731.831.5M14/25t** fits for VC 3 and VC 5
AEPøHfRBFLMJCbøGeNaKView XAnsicht XxKRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.eu21
GearType Flow Meter VC
Connection plates (cast iron) with rear threaded connection
OrderingcodeWeightkgmMVC 0.2 R 3 B 04*1.6MVC 0.4 R 1 C 08MVC 0.4 R 1 D 08MVC 1 R 2 C 04MVC 5 R 2 E 04**2.52.92.79.6A85B90C35374237E658686F769696G77779H1111111115J77779DimensionsmmK7080808446LMN6.516161225PRcdef40203834383472359550M6/14t28M8/18t46M8/18t52M8/18t50M12/24t550.7250.729136G3⁄813G1⁄215G3⁄417G1⁄215G119100110100110100120160165801060.72914255140145* fits for VC 0.025, VC 0.04, VC 0.1 and VC 0.2** fits for VC 3 and VC 5
AKCJGEøGPcMøHfRBLdConnection plates (cast iron) with rear SAE flange connection
OrderingcodeWeightkgm
MVC 5V2E04**A
B
C
E
F
G9H15J9DimensionsmmK46L
M
N
P
R
a
b
e
f
9.516016555140145Ne955025M12/24t8057.227.825M12/24t** fits for VC 3 and VC 5
APCJEføGMBLøHRbNKea22KRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.euFFGearType Flow Meter VC
Connection plates (Stainless steel) with side threaded connection
OrderingGewichtDimensionscodekgmmm
BDCEGHJKLMNPRefMVC0.2 R4 B11*1.78594357571177040206.5M6/14t18G3⁄813MVC1 R3 C113.211612437100915984723512M8/18t19.5G1⁄215MVC1 R2 D113.511612442100915984723512M8/18t21G3⁄417MVC 5 R2 E11**13.915817080140915946955025M12/24t52G119MVC5 R2 G11**17.91581701050140915946955025M12/24t63G11⁄223* fits for VC 0.025, VC 0.04, VC 0.1 and VC 0.2** fits for VC 3 and VC 5
ø DEPCJG øLMBH øefNRKKRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209 · mailinfo@kracht.eu · webwww.kracht.eu23
Product Portfolio
Transfer Pumps
Transfer pumps for lubricating oil supply equipment, low pressure filling and feed systems, dosing and mixing systems.
Flow Measurement
Gear and turbine flow meters and
electronics for volume and flow metering technology in hydraulics,
processing and laquering technology.
Mobile Hydraulics
Single and multistage high pressure gear pumps, hydraulic motors and valves for construction machinery, vehicle-mounted machines.
Industrial Hydraulics/Test Bench Construction
Cetop directional control and proportional valves, hydraulic cylinders, pressure, quantity and stop valves for pipe and slab construction, hydraulic accessories for industrial hydraulics (mobile and stationary use).
Technology Test benches / Fluid Test benches.
VC/GB/11.08KRACHTGmbH · Gewerbestraße20 · 58791 Werdohl, Germany · fon+49(0)2392/935-0 · fax+49(0)2392/935209
mailinfo@kracht.eu · webwww.kracht.eu
因篇幅问题不能全部显示,请点此查看更多更全内容