HOLD/GANTRY INVERTER(YS1000) /////////////////////////////////////////// OB09100 RUN .RUN

OB09101 REVERSE .REVERSE OB09102 B BLOCK .BASE BLOCK OB09103 TRACE .TRACE START OB09104 EXT FAU .EXTERNAL FAULT OB09105 RESET .FAULT RESET

OB09106 TIME CHG.LAU TIME CHANGE OB09107 SPD HOLD.SPEED HOLD

OB09108 INIT EXC.INITIAL EXCITATION OB09109 I RESET .ASR I RESET OB0910A I HOLD .ASR I HOLD OB0910B CANCEL .LAU CANCEL OB0910C TRACE .TRACE RESET OB0910D ZEROSERV.ZERO SERVO ON

OB0910E TORQ SEL.TORQUE CONTROL SELECT OB0910F 2MOTOR .NO.2 MOTOR SELECT OB09171 DO-2 .D/O-2(PHC1)

///////////////////////////////////////////

CLOSE/GANTRY INVERTER(YS1000) /////////////////////////////////////////// OB09300 RUN .RUN

OB09301 REVERSE .REVERSE OB09302 B BLOCK .BASE BLOCK OB09303 TRACE .TRACE START OB09304 EXT FAU .EXTERNAL FAULT OB09305 RESET .FAULT RESET

OB09306 TIME CHG.LAU TIME CHANGE OB09307 SPD HOLD.SPEED HOLD

OB09308 INIT EXC.INITIAL EXCITATION OB09309 I RESET .ASR I RESET OB0930A I HOLD .ASR I HOLD OB0930B CANCEL .LAU CANCEL OB0930C TRACE .TRACE RESET OB0930D ZEROSERV.ZERO SERVO ON

OB0930E TORQ SEL.TORQUE CONTROL SELECT OB0930F 2MOTOR .NO.2 MOTOR SELEC OB09371 DO-2 .D/O-2(PHC1)

/////////////////////////////////////////// LUFF INVERTER(H1000)

/////////////////////////////////////////// OB09500 RUN .RUN

OB09501 REVERSE .REVERSE OB09502 B BLOCK .BASE BLOCK OB09503 NO USE .NO USE

OB09504 EXT FAU .EXTERNAL FAULT OB09505 RESET .FAULT RESET OB09506 NO USE .NO USE OB09507 NO USE .NO USE OB09508 DB-ON .EXTERNAL DB ON OB09509 I RESET .ASR I RESET OB0950A NO USE .NO USE OB0950B NO USE .NO USE OB0950C NO USE .NO USE

OB0950D ZEROSERV.ZERO SERVO ON

OB0950E TORQ SEL.TORQUE CONTROL SELECT OB0950F NO USE .NO USE OB09571 DO .D/O(TERMINAL NO.26-27)

/////////////////////////////////////////// SLEW-1 INVERTER(H1000) /////////////////////////////////////////// OB09700 RUN .RUN

OB09701 REVERSE .REVERSE OB09702 B BLOCK .BASE BLOCK OB09703 NO USE .NO USE

OB09704 EXT FAU .EXTERNAL FAULT OB09705 RESET .FAULT RESET OB09706 NO USE .NO USE OB09707 NO USE .NO USE OB09708 DB-ON .EXTERNAL DB ON OB09709 I RESET .ASR I RESET OB0970A NO USE .NO USE OB0970B NO USE .NO USE OB0970C NO USE .NO USE

OB0970D ZEROSERV.ZERO SERVO ON

OB0970E TORQ SEL.TORQUE CONTROL SELECT OB0970F NO USE .NO USE OB09771 DO .D/O(TERMINAL NO.26-27)

/////////////////////////////////////////// SLEW-2 INVERTER(H1000) /////////////////////////////////////////// OB09900 RUN .RUN

OB09901 REVERSE .REVERSE OB09902 B BLOCK .BASE BLOCK OB09903 NO USE .NO USE

OB09904 EXT FAU .EXTERNAL FAULT OB09905 RESET .FAULT RESET OB09906 NO USE .NO USE OB09907 NO USE .NO USE OB09908 DB-ON .EXTERNAL DB ON OB09909 I RESET .ASR I RESET OB0990A NO USE .NO USE OB0990B NO USE .NO USE OB0990C NO USE .NO USE

OB0990D ZEROSERV.ZERO SERVO ON

OB0990E TORQ SEL.TORQUE CONTROL SELECT OB0990F NO USE .NO USE OB09971 DO .D/O(TERMINAL NO.26-27) 󰙵