Slim, Miniature Relay, Capable of
Relaying Programmable Controller and Temperature Controller Outputs
■■■■■■
G6D
Slim and miniature: 17.5 × 6.5 × 12.5 mm (L × W × H).
Ideal for high-density mounting.Switches 5 A at 250 VAC/30 VDC.
Allows 300,000 operations with a 2-A load at 250 VAC or 30 VDC.
Actual load switching capability equals the G6B’s capability.
Washable construction.
RCE
Enclosure ratings
Fully sealed
G6D-1A-ASI
Model
Ordering Information
Classification
Standard
Contact form
SPST-NO
Note: When ordering, add the rated coil voltage to the model number.Example: G6D-1A-ASI 12 VDCRated coil voltageModel Number Legend
G6D - - VDC12341. Number of Poles 1: 1 pole2. Contact Form A: SPST-NO■
3. Contact Material ASI: Silver alloy (cadmium-free)4. Rated Coil Voltage 5, 12, 24 VDCAccessories (Order Separately)
P6D-04P
Connecting Socket■
Coil Ratings
5 VDC40 mA125 Ω
70% max. of rated voltage10% min. of rated voltage160% of rated voltage (at 23°C)Approx. 200 mW
12 VDC16.7 mA720 Ω
24 VDC8.3 mA2,880 Ω
Rated voltageRated currentCoil resistanceMust operate voltageMust release voltageMax. voltagePower consumptionNote:
The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down.
1
G6D
■
G6D
Contact Ratings
5 A at 250 VAC, 5 A at 30 VDC, resistive load5 A
250 VAC, 30 VDC5 A
1,250 VA, 150 W10 mA at 5 VDC
–6Rated load
Rated carry currentMax. switching voltageMax. switching currentMax. switching powerFailure rate (reference value)Note:■
P level: λ60 = 0.1 x 10/operation
Characteristics
100 mΩ max.10 ms max.5 ms max.
1,000 MΩ min. (at 500 VDC)
3,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity6,000 V (1.2 x 50 µs) between coil and contacts
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)Destruction: 1,000 m/s2Malfunction: 100 m/s2
Mechanical:20,000,000 operations min. (at 18,000 operations/hr)Electrical:70,000 operations min. (5 A at 250 VAC/30 VDC, resistive load)
300,000 operations min. (2 A at 250 VAC/30 VDC, resistive load)Operating: −25°C to 70°C (with no icing)Operating: 5% to 85%Approx. 3 g
Contact resistanceOperate timeRelease timeInsulation resistanceDielectric strengthImpulse withstand voltageVibration resistanceShock resistanceEndurance
Ambient temperatureAmbient humidityWeight
Engineering DataMaximum Switching PowerSwitching current (A)5030EnduranceEndurance (x104 operations)500300Ambient Temperature vs. Maximum Coil VoltageMaximum coil voltage (%)200180160140120100806001053AC resistive load1005030250-VAC/30-VDC resistive loadDC resistiveload10.50.3DC inductiveloadAC inductive loadcosφ=0.4105250-VAC/30 VDC inductive load3(cosφ=0.4/ L/R=7 ms)0.103510301002505001,000100 1 2 3 4 5 6 7 8 9 2330405060708090Switching voltage (V)Switching current (A)Ambient temperature (°C)Ambient Temperature vs. Operating/Recovery Voltage G6D-1A-ASIOperating/recovery voltage (ratio of rated voltage) (%)100Malfunctioning Shock G6D-1A-ASIY1,000800X600400200ZNote: The maximum coil voltage is the maximum voltage that can be applied to the relay coilSample: G6D1AQuantity: 5 80Operating voltageRecovery voltagemax.60Xmin.40206max.Xmin.Z'Not energizedEnergized−20020406080X'YY'Unit: m/s220Shock directionXX'ZZ'Coil terminals0−40Y'Ambient temperature (°C)Measurement conditions: Impose a shock in the ±X, ±Y, and ±Z directions three times each with the Relay energized to check the shock values that cause the Relay to malfunction.2
G6D
■
G6D
Approved Standards
(File No. E41515) UL508
Number of poles1
Coil ratings5 to 24 VDC
Contact ratings
Number of test operations
•The rated values approved by each of the safety standards may be different from the performance characteristics individually defined inthis catalog.
UL Approval
ModelG6D-1A-ASI
5 A, 250 VAC (General Use)6,0005 A, 30 VDC
CSA Approval
ModelG6D-1A-ASI
(File No. LR31928) C22.2 No. 14
Number of poles1
Coil ratings5 to 24 VDC
Contact ratings
Number of test operations
5 A, 250 VAC (General Use)6,0005 A, 30 VDC (Resistive)
EN/TÜV Approval
ModelG6D-1A-ASI
(Registration No. R50029064/EN61810-1)
Coil ratings5, 12, 24 VDC
Contact ratings5 A, 250 VAC (cosφ=1.0)5 A, 30 VDC (0 ms)
Number of test operations70,000
Number of poles1
Dimensions
Note:
1.All units are in millimeters unless otherwise indicated.2.Orientation marks are indicated as follows: (6.4)*G6D-1A-ASI0.517.5 max.(17.3)* 6.5 max.Terminal Arrangement/Internal Connections (Bottom View)12.5 max.(12.4)*3.51572.542.54Mounting Holes(Bottom View)Tolerance: ±0.1Four, 1.1-dia.holes(0.71)0.52.540.87.62.5.085.080.3135.08*Average valueP6D-04P Socket6.9 max.(6.7)*19.7 max.(19.5)*(1.13)10.165.08Mounting Holes(Bottom View)Tolerance: ±0.1Four, 1.1-dia. (2.18)holes(0.86)10.82.546+0.13.60.652.540.376.25.08*Average value15.245.082.543
G6DG6D
Precautions
More than two relays can be closely mounted right side up as shown in the following illustration.
6.5 mm18.5 mm max.Socket Mounting Height
Current flow: 5 A max.More than two relays can be closely mounted upside down as shown in the following illustration.
7.62 mm in the upside-down directionWhen mounting the relay, insert it into the socket as vertically as possible so that the relay terminals contact securely with the con-tact pins on the socket.
The P6D is flux-resistive. Do not wash the P6D with water.
Dismount the relay from the socket before soldering the socket to a PCB.
Current flow: 2 A max.1.12 mmNote:
The space between each relay required for heat radiationmay vary with operating conditions. Contact your OMRONrepresentative for details.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
Cat. No. K127-E1-02In the interest of product improvement, specifications are subject to change without notice.
OMRON RELAY & DEVICES CorporationC&C Power Relay DivisionMarketing Department1110 Sugi, Yamaga-City,Kumamoto, 861-0596 Japan
Tel: (81)968-44-4160/Fax: (81)968-44-4107
Printed in Japan1208