Flanges PN 6 EN 1092-1
Dimensions of PN 6 Flanges EN 1092-1
NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. NOTE 2: For d1 dimensions see document \"Flange facing according to EN 1092-1\".
Dimensions in mm
* Above DN 600 dimension C1 is to be specified by the purchaser.
** For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter.
NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.
Flanges PN 10 EN 1092-1
Dimensions of PN 10 Flanges EN 1092-1
NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. NOTE 2: For d1 dimensions see document \"Flange facing according to EN 1092-1\".
Dimensions in mm
* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter,
NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.
Flanges PN 16 EN 1092-1
Dimensions of PN 16 Flanges EN 1092-1
NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. NOTE 2: For d1 dimensions see document \"Flange facing according to EN 1092-1\".
Dimensions in mm
* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter, ** 8 holes is preferred however 4 holes may be supplied upon special request by the purchaser.
NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.
Flanges PN 25 EN 1092-1
Dimensions of PN 25 Flanges EN 1092-1
NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. NOTE 2: For d1 dimensions see document \"Flange facing according to EN 1092-1\".
Dimensions in mm
* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter.
NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.
Flanges PN 40 EN 1092-1
Dimensions of PN 40 Flanges EN 1092-1
NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. NOTE 2: For d1 dimensions see document \"Flange facing according to EN 1092-1\".
Dimensions in mm
* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter,
NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.
Flanges PN 63 EN 1092-1
Dimensions of PN 63 Flanges EN 1092-1
NOTE: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.
Dimensions in mm
* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter.
NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.
Flanges PN 100 EN1092-1
Dimensions of PN 100 Flanges EN 1092-1
NOTE: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.
Dimensions in mm
* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter,
NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.
Type A flat face
FLANGES according to EN 1092-1
Flange facing dimensions according to EN 1092-1 standard
Type B Type C raised face
tongue face
Type D groove face
Type E spigot
Type F recces
Type G O ring recess
Type H O ring groove
* For PN 160 flnages form can be only B2, C and D